Language:
简体中文
400-612-5080
Stock Code:300371

SCL-61D5/D6 Ultrasonic Water Meter (Stainless Steel Casing)

Time:2021.11.16 Text Size: Large Medium Small Share:
ItemParameter
SCL-61D5(Reducing Diameter)

Fluid

Full pipe of Water, sewage, or homogeneous fluids
Accuracy ClassClass 2
Dynamic RangeR400,R500
Nominal DiameterDN50~DN300

Maximum Allowable WorkingPressure

1.0MPa/1.6MPa/2.5MPa, Default is 1.6MPa (only DN200 is default in 1.0MPa)
Pressure LossΔp 10

Working Environment

-25℃~55℃,≤100%RH
TemperatureT30, T50

Upstream Sensitivity Class

U0

Downstream Sensitivity Class

D0

Climate Environment

Class O
Electromagnetic CompatibilityE2
Communication

PhotoelectricInterface

Baud Rate 2400bps, use EN13757 protocol

RS-485/M-Bus

Baud Rate 2400bps, 4800bps, 9600bps (selectable), default is 2400bps, transmission distance<1200m.EN13757 protocol

Data StorageEEPROM applied for cumulative volume and time, automatically storage daily historical data and latest24 months data, stored for 100years in power failure
Power

Lithium battery powered DC3.6V, the battery works continuously over 10 years

DC10V-DC36V,220mA(specific requirement prior to order)
Protection ClassIP68

The length of the cable from the split display unit to the meter is 1.5m as standard, and the special length should be proposed at the timeof order.

 


Item
Parameter
SCL-61D6 (Diameter Pipe)

Fluid

Full pipe of Water, sewage, or homogeneous fluids
Accuracy ClassClass 2
Dynamic RangeR400
Nominal DiameterDN50~DN300

Maximum Allowable WorkingPressure

1.0MPa/1.6MPa/2.5MPa, Default is 1.6MPa (only DN200 is default in 1.0MPa)
Pressure LossΔp 10

Working Environment

-25℃~55℃,≤100%RH
TemperatureT30, T50

Upstream Sensitivity Class

U0

Downstream Sensitivity Class

D0

Climate Environment

Class O
Electromagnetic CompatibilityE2
Communication

PhotoelectricInterface

Baud Rate 2400bps, use EN13757 protocol

RS-485/M-Bus

Baud Rate 2400bps, 4800bps, 9600bps (selectable), default is 2400bps, transmission distance<1200m.EN13757 protocol

Data Storage

EEPROM applied for cumulative volume and time, automatically storage daily historical data and latest24 months data, stored for 100years in power failure

Power

Lithium battery powered DC3.6V, the battery works continuously over 10 years

DC10V-DC36V,220mA(specific requirement prior to order)

Protection ClassIP68

The length of the cable from the split display unit to the meter is 1.5m as standard, and the special length should be proposed at the timeof order.

 


Support & Cooperation

Please contact us at any time if you have questions in product selection, material procurement, as well as business & technology cooperation.