News List
SCL-61D5/D6 Ultrasonic Water Meter
| Item | Parameter | |||||||||
| SCL-61D5(Reducing Diameter) | ||||||||||
Fluid | Full pipe of Water, sewage, or homogeneous fluids | |||||||||
| Accuracy Class | Class 2 | |||||||||
| Dynamic Range | R400,R500 | |||||||||
| Nominal Diameter | DN50~DN300 | |||||||||
Maximum Allowable WorkingPressure | 1.0MPa/1.6MPa/2.5MPa, Default is 1.6MPa (only DN200 is default in 1.0MPa) | |||||||||
| Pressure Loss | Δp 10 | |||||||||
Working Environment | -25℃~55℃,≤100%RH | |||||||||
| Temperature | T30, T50 | |||||||||
Upstream Sensitivity Class | U0 | |||||||||
Downstream Sensitivity Class | D0 | |||||||||
Climate Environment | Class O | |||||||||
| Electromagnetic Compatibility | E2 | |||||||||
| Communication | PhotoelectricInterface | Baud Rate 2400bps, use EN13757 protocol | ||||||||
RS-485/M-Bus | Baud Rate 2400bps, 4800bps, 9600bps (selectable), default is 2400bps, transmission distance<1200m.EN13757 protocol | |||||||||
| Data Storage | EEPROM applied for cumulative volume and time, automatically storage daily historical data and latest24 months data, stored for 100years in power failure | |||||||||
| Power | Lithium battery powered DC3.6V, the battery works continuously over 10 years | |||||||||
| DC10V-DC36V,220mA(specific requirement prior to order) | ||||||||||
| Protection Class | IP68 | |||||||||
The length of the cable from the split display unit to the meter is 1.5m as standard, and the special length should be proposed at the timeof order. | ||||||||||
Item | Parameter | |||||
| SCL-61D6 (Diameter Pipe) | ||||||
Fluid | Full pipe of Water, sewage, or homogeneous fluids | |||||
| Accuracy Class | Class 2 | |||||
| Dynamic Range | R400 | |||||
| Nominal Diameter | DN50~DN300 | |||||
Maximum Allowable WorkingPressure | 1.0MPa/1.6MPa/2.5MPa, Default is 1.6MPa (only DN200 is default in 1.0MPa) | |||||
| Pressure Loss | Δp 10 | |||||
Working Environment | -25℃~55℃,≤100%RH | |||||
| Temperature | T30, T50 | |||||
Upstream Sensitivity Class | U0 | |||||
Downstream Sensitivity Class | D0 | |||||
Climate Environment | Class O | |||||
| Electromagnetic Compatibility | E2 | |||||
| Communication | PhotoelectricInterface | Baud Rate 2400bps, use EN13757 protocol | ||||
RS-485/M-Bus | Baud Rate 2400bps, 4800bps, 9600bps (selectable), default is 2400bps, transmission distance<1200m.EN13757 protocol | |||||
| Data Storage | EEPROM applied for cumulative volume and time, automatically storage daily historical data and latest24 months data, stored for 100years in power failure | |||||
| Power | Lithium battery powered DC3.6V, the battery works continuously over 10 years | |||||
DC10V-DC36V,220mA(specific requirement prior to order) | ||||||
| Protection Class | IP68 | |||||
The length of the cable from the split display unit to the meter is 1.5m as standard, and the special length should be proposed at the timeof order. | ||||||
Please contact us at any time if you have questions in product selection, material procurement, as well as business & technology cooperation.
Service Hotline
400-612-5080
Huizhong Instrumentation Co., Ltd. ICP:Ji ICP Bei No. 11006660-1 Company address:No.126 West Gaoxin Road, High Tech Industrial Zone, Tangshan, Hebei
Company telephone:400-612-5080 0315-3296878 3296898
Jgw Anbei No. 13024002000217