SCL-715/716 Ultrasonic Flowmeter

Features:
1. Online self-verification function for the accuracy of deployed products.
2. Integrated mechanical design with protection class of IP68, able to work in long-term water immersion.
3. Low initial flowrate and high measurement accuracy.
4. Fine stability, long-term work at any flow point, and no magnetic interference.
5. Water temperature measurement function for monitoring the temperature change of process.
6. Multiple transmission methods, RS-485, 4-20mA+HART, RF radio frequency and NB-IoT.
7. Energy saving and environmental protection, no casting and pollution.
8. Micro power consumption technology, battery powered/dual power supply.
9. Not affected by temperature, pressure and conductivity (no conductivity requirement).
Advantages:
1. 4-channel design for all series, dual-fracture surface measuring method, improve the accuracy under complex flow regime.
2. Recyclable stainless-steel pipe for the reduction of use costs.
3. Ultrasonic measuring technology with diameter pipe design, no pressure loss mechanical and moving parts, reduces power loss.
4. Integrated flowrate and pressure measurement, able to reach the demand of monitoring.
5. Be designed into common type, bidirectional type and fire-fighting type according to the needs of users.
6. Intelligent manufacturing for flexible customization.
Benefits:
It is suitable for accurate measurement and trade settlement of the master-meter flowrate of urban water supply pipeline and household metering, and also suitable for DMA district metering management, which solves the problems of high initial flowrate and non-measurement of small flowrate in traditional meters.

Consulting Hotline:+86 400-612-5080

E-mail Address:info@hzyb.com

*Take the product actually used as the criterion

Technical Parameters
ItemParameter
Product TypeSCL-715SCL-716
Accuracy ClassClass 0.5Class 0.5/Class 1/Class 2
Nominal DiameterDN50~DN200DN50~DN300
Number of Sonic Channels4-channels
MediumWater, sewage or other homogeneous fluids in full pipe flow
Max. Permissible Pressure of Transducer1.0MPa/1.6MPa/2.5MPa, default: 1.6MPa (only 1.0MPa for DN200)
Working Environment of Main Unit-25℃~55℃,≤100%RH
Class of Upstream Flow Field SensitivityU0
Class of Downstream Flow Field SensitivityD0
Category of Climate & Mechanical Environment ConditionsClass C
Class of Electromagnetic CompatibilityE2
Data CommunicationOptical Interface/RS-485/Wireless Communication/Analogy Switch Output
Data StorageUsing EEPROM for storage of cumulative flowrate and cumulative running time; Data can be stored for 100 years after power failure; The data of the past 24 months can be automatically stored
Power Supply

Battery powered, one battery can work continuously over 10 years,

DC10V~DC36V,≥20mA (please specify on ordering)

Protection ClassIP68
For the non-integral meter version, the cable connecting the measuring unit and display is in a standard length of 1.5m. For cable length other than this, please specify on ordering.


Support & Cooperation

Please contact us at any time if you have questions in product selection, material procurement, as well as business & technology cooperation.

Huizhong Instrumentation Co., Ltd. ICP:Ji ICP Bei No. 11006660-1 Company address:No.126 West Gaoxin Road, High Tech Industrial Zone, Tangshan, Hebei

Company telephone:400-612-5080 0315-3296878 3296898 Jgw Anbei No. 13024002000217